The Fluke® 381 does everything you would expect from a clamp meter/and then lets you remove the display for even more flexibility. Now one technician can do jobs that used to require two people. Clamp the Fluke® 381 around a conductor/remove the display and walk across the room to operate controls or remove protective equipment/all while watching real time readings. The iFlex" flexible current probe (included) expands the measurement range to 2500 A AC while providing increased display flexibility/ability to measure awkward sized conductors and improved wire access.
Fluke® Clamp Meter, 999.9 A. 600 VAC, 1000 VDC Electrical Rating, 60 kOhm Resistance, 500 Hz Frequency, 34 mm Jaw, Removable Wireless Display, 2% +/-5 Digits at 999.9 A, 3% +/-5 Digits at 2500 A AC Current Accuracy, 1.5% +/-5 Digits at 1000 VAC, 1% +/-5 Digits at 1000 VDC Voltage Accuracy, Safety Rating: CAT IV 600 VAC/CAT III 1000 VAC, -10 to 50 deg C Operating, 10.9 in L x 3.46 in W x 1.69 in H Dimensions, Hard Plastic
AC Current Accuracy |
: |
2% +/-5 Digits at 999.9 A, 3% +/-5 Digits at 2500 A |
Dimensions |
: |
10.9 in L x 3.46 in W x 1.69 in H |
Material |
: |
Hard Plastic |
Operating Temperature |
: |
-10 to 50 deg C |
Safety Rating |
: |
CAT IV 600 VAC/CAT III 1000 VAC |
Voltage Accuracy |
: |
1.5% +/-5 Digits at 1000 VAC, 1% +/-5 Digits at 1000 VDC |
Electrical Ratings |
: |
999.9 A. 600 VAC, 1000 VDC |
Resistance |
: |
60 kOhm |
Frequency Rating |
: |
500 Hz |
Jaw Capacity |
: |
34 mm |
Display Type |
: |
Removable Wireless |
- Wireless technology allows the display to be carried up to 30 ft away from the point of measurement for added flexibility without interference with measurement accuracy
- The removable magnetic display can be conveniently mounted where it is easily seen
- IFlex® flexible current probe expands the measurement range to 2500 A AC
- CAT IV 600 VAC/VDC, CAT III 1000 VAC/VDC
- Integrated low pass filter and state-of the art signal processing allows for use in noisy electrical environments while providing stable readings
- Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
- Ergonomic design fits in your hand and can be used while wearing protective equipment
- Radio transmitter automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
- Soft carrying case
- Accuracy - 2% +/-5 digits dc current/1.5% +/-5 digits (20 to 500 Hz) AC voltage/1% +/-5 digits dc voltage/ 1% +/-5 digits resistance
- Resolution - 0.1 A AC current via jaw/0.1 A (</=600 a)/1 A (</=2500 a) AC current via flexible current probe/0.1 a DC current/0.1 VAC voltage/0.1 VDC voltage/0.1 Ohm/1 Ohm/10 Ohm resistance
- 2000 m operating altitude, 12000 m storage altitude
- 7.5 mm flexible current probe diameter
- 1.8 m flexible current probe cable length (head to electronics connector)
- Add 0.1 x specified accuracy for each deg C above 28 deg C or below 18 deg C temperature coefficients
- 3 at 500 A, 2.5 at 600 A, 1.42 at 1000 A, add 2% for C.F, >2 AC current via jaw/3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2% for C.F, >2 2 AC current via flexible current probe crest factor (50/60 Hz)
- <=30 Ohm measure continuity
- 100 ms measure inrush
- Range 5 to 500 Hz frequency via jaw and flexible current probe, 600 Ohm/6 kOhm/60 kOhm resistance, 2% +/-5 digit (10 to 100 Hz), 5% +/-5 digit (100 to 500 Hz) via jaw, 3% +/-5 digit via flexible current probe AC current accuracy, 1.5% +/-5 digit (20 to 500 Hz) AC voltage, 1% +/-5 digit DC voltage accuracy
-
Specification Sheet
https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_addb2b5eafd8be9988346c735f147a6d86e3f99e57ed049774535ddd45b683f0.pdf