For the complete solution to HVAC troubleshooting the extra value-packed HVAC Technician's Combo kit, provides the ability to troubleshoot and solve problems more efficiently by providing all the needed accessories an HVAC professional would need in a compact carry case.
Fluke® HVAC Technician's Combo Kit, 600 VAC Max Voltage, 6000 Count Display, 9 VDC Alkaline Battery, 167 mm x 84 mm x 46 mm HVAC Multimeter, 175 mm x 85 mm x 75 mm 62 MAX+ Infrared Thermometer
Dimensions |
: |
167 mm x 84 mm x 46 mm HVAC Multimeter, 175 mm x 85 mm x 75 mm 62 MAX+ Infrared Thermometer |
Specifications |
: |
600 VAC Max Voltage, 6000 Count Display, 9 VDC Alkaline Battery |
- Fluke® 116 HVAC multimeter with temperature and micro amps, TL175 Hard Point® test lead set, TPak ToolPak® magnetic meter hanging strap, flexible cuff pipe clamp thermocouple, 80BK integrated temperature probe
- 80AK-A thermocouple adapter, C115 deluxe soft carrying case with shoulder strap
- Fluke® 62 MAX+ small in size, big on toughness, dust and water-resistant: IP54 rated, rugged 3 meter (9.8 ft) drop tested, ergonomically designed - completely redesigned for a more natural hand fit, distance to spot 12:1, dual lasers identifies area to be measured
- Fluke® 62 MAX+ - large, backlit display makes data easier to read, even in dark areas
- 600 mV range, 0.1 mV resolution, 1.0% + 3 (DC, 45 Hz to 500 Hz)/2.0% + 3 (500 Hz to 1 kHz)
- Continuity - 600 ohm range, 1 ohm resolution, beeper on < 20 ohm, Off > 250 ohm, detects opens or shorts of 500 us or longer
- Diode test - 2 V/0.001 V range/resolution, 0.9% + 2 accuracy
- Capacitance - 1000 nF/1 nF, 10.00 uF/0.01 uF, 100.0 uF/0.1 uF, 9999 uF/1 uF, 100 uF to 1000 uF range/resolution, 1.9% + 2 accuracy, > 1000 uF range/resolution, 5% + 20% accuracy
- LoZ capacitance - 1 nF to 500 uF range, 10% + 2 typical accuracy
- Temperature2 (Type K thermocouple) -40 to 400 deg C/0.1 deg C range/resolution, 1% + 102 accuracy, -40 to 752 deg F/0.2 deg F range/resolution, 1% + 182 accuracy
- 99.99 Hz/0.01 Hz, 999.99 Hz/0.1 Hz, 9.999 Hz/0.001 Hz, 50 Hz/0.01 Hz, 0.1% + 2 Hz range/resolution, 0.1% + 2 accuracy (V or A input)2
- Battery with 400 hr life for 116 HVAC multimeter
- -30 to 650 deg C temperature
- <300 ms (95% of reading) response time for 62 MAX+ infrared thermometer
- Built-in thermometer for HVAC applications
- Microamps to test flame sensors
- Low input impedance helps prevent false readings due to ghost voltage
- Work in poorly lit areas with the Large white LED backlit display
- True-RMS voltage and current for accurate measurements on non-linear loads
- Measures 10 A directly (20 A overload for 30 sec) without a current clamp
-
Catalog
https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_2f1edfd2e686ce7b17ddd7170d25fd5e4bec9a6b1f4e27263ecb3a4c82e711ab.pdf
-
Instruction/Installation Manual
https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_1480759069965.pdf
-
VIDEO LINK
http://download.fluke.com/demo-IAD/116_demo.html
-
Warranty Information
https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_46666252c3f9fdf4cfaa53846c0258ce7937351d2e976fd9e30f9754cf28462e.pdf