NSI 3002 3002 TK | Fromm
Send Print
  1. pin-int

NSI 3002

NSI 3002 3000 Button Photocontrol, 208 to 277 VAC, 3470 to 4620 W Tungsten, 2080 to 2770 VA Ballast, Flush Mount, Lexan

  • Manufacturer Name: NSi Industries
  • MPN: 3002
  • Brand Name: NSI
  • UPC: 786261600196
  • FEPN: 3002 TK
  • Min Order Qty: 1
  • Quantity Interval: 1
  • Inventory Availability loading

NSI Photocontrol, Button, Series: 3000, 208 to 277 VAC, 50/60 Hz, 3470 to 4620 W Tungsten, 2080 to 2770 VA Ballast, SPST, 2 min, 16 AWG Wire, Cadmium Sulfide Cell Sensor, 1 to 5 FC (ON)/3 to 15 FC (OFF) Ratio, Environmental Conditions: -40 to 140 deg F Operating Temperature, Flush Mount, Lexan, Black, 2 in H x 2-1/4 in D

Color       :      Black
Contact Form       :      SPST
Dimensions       :      2 in H x 2-1/4 in D
Environmental Conditions       :      -40 to 140 deg F Operating Temperature
Frequency Rating       :      50/60 Hz
Sensitivity       :      1 to 5 FC (ON)/3 to 15 FC (OFF) Ratio
Sensor Type       :      Cadmium Sulfide Cell
Series       :      3000
Timing Range       :      2 min
Type       :      Button
Wire Size       :      16 AWG
Voltage Rating       :      208 to 277 VAC
Tungsten Rating       :      3470 to 4620 W
Ballast Load       :      2080 to 2770 VA
Mounting Type       :      Flush
Material       :      Lexan
  • Conformal coated cadmium sulphide photocell resists effects of moisture and airborne contaminants
  • Photocell responds to the light spectrum near to that of a human eye
  • Delay of up to two minutes to prevent false switching due to light from passing vehicles, lightning and more
  • Control housing is weather resistant molded Lexan® with ultrasonically welded seams
  • Flush mounting through 11/16 in hole in post lantern or lighting fixture, 3/8 in NPT, stem 3/4 in long
  • Works with screw base CFL
  • On and Off time delay
  • Cadmium sulphide, conformal coated 1/2 in diameter cell
  • Three color coded, minimum 9 in wire leads, 16 AWG, rated for 105 deg C lead wires
  • Averages under 1 W power consumption
  • On fail mode
  • pdfCatalog https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_9a677abbe0f087ac343a04b05c904dae13839856d98aaa0223720ad23f286c73.pdf
  • pdfSpecification Sheet https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_ea4f0ee603c92e3b9580099838aa52c111af75c8ae0559153306947d803db230.pdf