Loadcenters are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.
EATON Main Breaker Load Center, 1-Phase, 120/240 VAC, 100 A, 1 Pole, 10 kA Interrupt, 30 Circuits, BR Breaker, 3-Wire Wiring Configuration, 30 Spaces, 4 to 1/0 AWG Wire, Plug-On Mounting, NEMA 1 Enclosure, X5 Enclosure Box, Galvanized Steel Housing Material, 29 in L x 14.31 in W x 3.88 in H Dimensions
Breaker Type |
: |
BR |
Dimensions |
: |
29 in L x 14.31 in W x 3.88 in H |
Enclosure Box Size |
: |
X5 |
Enclosure Type |
: |
NEMA 1 |
Housing Material |
: |
Galvanized Steel |
Mounting Type |
: |
Plug-On |
Number of Circuits |
: |
30 |
Number of Spaces |
: |
30 |
Type |
: |
1-Phase |
Wire Size |
: |
4 to 1/0 AWG |
Wiring Configuration |
: |
3-Wire |
Voltage Rating |
: |
120/240 VAC |
Amperage Rating |
: |
100 A |
Number of Poles |
: |
1 |
Interrupt Rating |
: |
10 kA |
- Extra 1-1/2 in knockout, larger knockout provides easier installation and time savings for renovation installations
- Straight-in wiring saves labor and material
- One panel for either top or bottom applications
- 2/0 AWG lug, easily removable and can be installed in any location on the neutral bar
- Type BR AFCI breakers, compact design for easier wiring and improved wireway access, provides a clean gutter space
- Standard Tin-plated aluminum bus for excellent conductivity and corrosion-resistance
- Tangential center knockout - easier installation for conduit applications
- Commercial grade main breaker, 25 kA series rated main breaker for superior protection
- Neutral bus, easily removable for sub-panel applications
- Bonding Z-strap, provides easy field conversion for service entrance applications
- Steel backpan provides solid and reliable breaker mounting, single piece design for stability and durability
- 4 to 1/0 AWG copper/aluminum wire size
-
Catalog
https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_4699c4093f200f15c8feec0c1d17577c692ad449e7fa8bead4e77755afaf41b2.pdf
-
Instruction/Installation Manual
https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/EATON_BR40SPAST_Manual.pdf
-
Specification Sheet
https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/EATON_BRP30BC100_Specification_Sheet.pdf