EATON 10316H1600 10316H1600 EC | Fromm
Send Print
  1. pin-int

EATON 10316H1600

EATON 10316H1600 Type LP Pneumatic Time Delay Limit Switch, 120 VAC/VDC, 0.2/10 A, Side Rotary Actuator, 1NO-1NC Contact

  • Manufacturer Name: Eaton
  • MPN: 10316H1600
  • Brand Name: EATON
  • UPC: 782113266336
  • FEPN: 10316H1600 EC
  • Min Order Qty: 1
  • Quantity Interval: 1
  • Inventory Availability loading

Type LX, CX and CBX limit switches are designed for extreme environmental service in NEMA 7 9 locations where the danger of an internal or external explosion of flammable gases, vapors, metal alloy or grain dust exists. Type CB provides excellent corrosion-resistant properties in NEMA 4X applications. Markets served include mining, grain storage, forest products, petrochemical, pharmaceutical and waste and sewage management.

EATON Time Delay Limit Switch, Type LP Pneumatic, Series: 10316, 120 VAC/VDC, 0.2/10 A, 1NO-1NC Contact Configuration, 10 A at 120 VAC, 0.2 A at 120 VDC Contact, CW/CCW/Spring Return to Center Action, Side Rotary Actuator, Screw/Thread Connection, NEMA 4/13 Enclosure, 1.55 in L x 5.06 in W x 1.78 in H Size, 32 to 149 deg F Operating, Die-cast Zinc

Action       :      CW/CCW/Spring Return to Center
Connection Type       :      Screw/Thread
Contact Rating       :      10 A at 120 VAC, 0.2 A at 120 VDC
Enclosure Type       :      NEMA 4/13
Material       :      Die-cast Zinc
Operating Temperature       :      32 to 149 deg F
Series       :      10316
Size       :      1.55 in L x 5.06 in W x 1.78 in H
Type       :      Type LP Pneumatic
Voltage Rating       :      120 VAC/VDC
Amperage Rating       :      0.2/10 A
Actuator       :      Side Rotary
Contact Configuration       :      1NO-1NC
  • 10 deg pre travel
  • 50 deg total travel
  • On delay timed contacts
  • CW and CCW direction of rotation
  • 0.05 to 60 sec timing range
  • 1/2 in NPT conduit entrance
  • With 15 sec or higher interval between timing periods +/-10% of setting maximum, with less than 15 sec interval between timing periods: +/-25% of setting maximum is repeat accuracy
  • On delay function timing begins when lever is actuated and held
  • 250 operations per minute maximum
  • pdfCatalog https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_5e9ad6d456a9436a9c9f30b495e6a53d1a46e6f061a00d8a446c1ff4e5580f9b.pdf
  • pdfSpecification Sheet https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_37857304f2194f1be167bf8e5e6c41ffc293fa0f78a0f7e4037121ba1b9a6d5d.pdf