EATON BR48L125FP BR48L125FP EC | Fromm
Send Print
  1. pin-int

EATON BR48L125FP

EATON BR48L125FP 1-Phase Split Main Lug Loadcenter, 120/240 VAC, 125 A, 8 Poles, 10 kA Interrupt

  • Manufacturer Name: Eaton
  • MPN: BR48L125FP
  • Brand Name: EATON
  • UPC: 786676001717
  • FEPN: BR48L125FP EC
  • Min Order Qty: 1
  • Quantity Interval: 1
  • Inventory Availability loading

Load centers are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.

EATON Main Lug Loadcenter, 1-Phase Split, 120/240 VAC, 125 A, 8 Pole, 10 kA Interrupt, 8 Circuits, BR Breaker, 3-Wire Wiring Configuration, 4 Spaces, 14 to 1/0 AWG Wire, Flush Mount, NEMA 1, NEMA 7 Enclosure Box, 3.56 in L x 11 in W x 13 in H

Breaker Type       :      BR
Dimensions       :      3.56 in L x 11 in W x 13 in H
Enclosure Box Size       :      NEMA 7
Enclosure Type       :      NEMA 1
Mounting Type       :      Flush
Number of Circuits       :      8
Number of Spaces       :      4
Type       :      1-Phase Split
Wire Size       :      14 to 1/0 AWG
Wiring Configuration       :      3-Wire
Voltage Rating       :      120/240 VAC
Amperage Rating       :      125 A
Number of Poles       :      8
Interrupt Rating       :      10 kA
  • Twin neutral design located in wireway, away from circuit breakers, means easier wiring and balancing of the load
  • Extra 1-1/2 in knockout for bundling allows maximum wiring gutter space for ease of wiring in compliance with NEC requirements
  • 1-piece roll formed metal backpan with circuit breaker alignment notches ensures accurately aligned breaker and bus tabs
  • Standard 14-3/8 in W enclosures fit snugly between wall studs
  • Tangential main knockouts eliminates the need for conduit offsets, which permits faster, easier installation
  • BR load centers feature Robertson slotted square combo screw heads, which means only one screwdriver is need for installation
  • For use with type BR 1 in breakers
  • Without cover
  • Indoor enclosure
  • Copper/aluminum wire at 60 to 75 deg C for main lugs
  • Standard tin plated aluminum bus for excellent conductivity and corrosion-resistance
  • Current design
  • pdfCatalog https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_4699c4093f200f15c8feec0c1d17577c692ad449e7fa8bead4e77755afaf41b2.pdf
  • pdfInstruction/Installation Manual https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_ca16bd8f5db476d34fa75b41ece3caa72dc141327f68d7a38a79a60d860a17b7.pdf
  • pdfSpecification Sheet https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_af16ad2bce2be6ced20bf09f0b9ca7574315bf65645206883ab323ba8dbd83d3.pdf