Bussmann FNQ-R-10 FNQ-R-10 BU | Fromm
Send Print
  1. pin-int

Bussmann FNQ-R-10

Bussmann Limitron™ FNQ-R-10 Current Limiting Time Delay Fuse, 10 A, 600 V, 200 kAIC Interrupt, CC Class, Cylindrical Body

  • Manufacturer Name: Eaton
  • MPN: FNQ-R-10
  • Brand Name: Bussmann
  • UPC: 051712497091
  • FEPN: FNQ-R-10 BU
  • Min Order Qty: 1
  • Quantity Interval: 10
  • Inventory Availability loading

Eaton Bussmann series Limitron™ fuses provide short circuit protection that is, on average, 10X faster than basic circuit breakers or fuses. These current-limiting UL and CSA Listed fuses are available in Class CC, J, R, and T - all with a 200 kA interrupting rating.

Bussmann Limitron™ Fuse, Current Limiting Time Delay, Series: FNQ-R, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 10 A, 600 V, 200 kAIC Interrupt, Class: CC, 12 s at 200% Response, Ferrule End Terminal, Holder Mount, Cylindrical Body Type, Dual Element, Melamine Tube, 13/32 in Dia x 1-1/2 in L Body Size

Body Size       :      13/32 in Dia x 1-1/2 in L
Element       :      Dual
Indicating/Non-Indicating       :      Non-Indicating
Material       :      Melamine Tube
Mounting Type       :      Holder
Rejection/Non-Rejection       :      Rejection
Response Time       :      12 s at 200%
Series       :      FNQ-R
Terminal Type       :      Ferrule End
Type       :      Current Limiting Time Delay
Amperage Rating       :      10 A
Voltage Rating       :      600 V
Interrupt Rating       :      200 kAIC
Class       :      CC
Body Type       :      Cylindrical
  • Provides 10X better current limitation to help prevent equipment damage caused by short circuit events
  • 200 kA interrupt rating complies with NEC section 110.9 for todays large capacity systems
  • Fast acting fuse helps prevent equipment damage caused by short circuit events
  • Rejection type fuse fits both standard and rejection style holders
  • The class CC FNQ-R Limitron fuse meets the needs of control circuit transformer protection
  • FNQ-R fuses can be sized according to NEC and UL requirements and still allow the high inrush currents, with significantly more time delay than the UL minimum value of 12 s at 200% for class CC fuses
  • Nickel plated brass end caps
  • 200 kA AC (RMS symmetrical)
  • pdfCatalog https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_b130f1135a6a844e814664dd9f51735b6b291ccabd1f2df97c5924983239479f.pdf
  • pdfLine Drawing https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_baa73323533155c0b25685084d104fe61ff1beb9e2908709d0e30ce41821ea73.pdf
  • pdfSpecification Sheet https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_5fc55ea11cb1a493c2315347061c4a0f71de9ddf19b860b325394b84c3d689db.pdf
  • videoVIDEO LINK https://www.youtube.com/watch?v=YMvqUyoETXk