EATON BR816L125RP

EATON BR816L125RP 1-Phase Main Lug Loadcenter, 120/240 VAC, 125 A, 16 Poles, 10 kA Interrupt

  • Manufacturer Name: Eaton
  • MPN: BR816L125RP
  • Brand Name: EATON
  • UPC: 786676001472
  • FEPN: BR816L125RP EC
  • Min Order Qty: 1
  • Quantity Interval: 1
  • Inventory Availability loading

Specially designed for easy installation, Eaton's BR 1-inch load centers house the branch circuit breakers and the wiring required to distribute power to individual circuits. They serve as main breaker for service entrances or as main lug when adding circuits to existing service. The main breaker protects the entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.

EATON Main Lug Loadcenter, 1-Phase, 120/240 VAC, 125 A, 16 Pole, 10 kA Interrupt, 16 Circuits, BR Breaker, 3-Wire Wiring Configuration, 8 Spaces, 14 to 1 AWG Wire, Surface Mounting, NEMA 3R Enclosure, NEMA 7R Enclosure Box, Metal Housing Material, 3.56 in L x 11 in W x 13 in H

Breaker Type       :      BR
Dimensions       :      3.56 in L x 11 in W x 13 in H
Enclosure Box Size       :      NEMA 7R
Enclosure Type       :      NEMA 3R
Housing Material       :      Metal
Mounting Type       :      Surface
Number of Circuits       :      16
Number of Spaces       :      8
Type       :      1-Phase
Wire Size       :      14 to 1 AWG
Wiring Configuration       :      3-Wire
Voltage Rating       :      120/240 VAC
Amperage Rating       :      125 A
Number of Poles       :      16
Interrupt Rating       :      10 kA
  • Current design
  • Aluminum bus material
  • Single-phase
  • Ground bar kits priced separately
  • For 2/4 circuit loadcenters, use GBK5 or GBK520 ground bar
  • Ground bars mount to the left side wall of the enclosure for the 4/8, 6/12 and 8/16 circuit loadcenters
  • Rainproof panels are furnished with hub closure plates, for rainproof hubs
  • Suitable for use as service equipment when a main breaker is used or when not more than six service disconnecting mains are provided
  • Insulated/bondable split neutral type
  • 1 in maximum space