Bussmann's UL Class RK5 Fusetron product offering provides energy efficient advanced protection with its dual-element, time-delay construction and is available with optional open fuse indication on select ratings. Available in both 250Vac and 600Vac, 200kA RMS Sym interrupting rating and sizes ranging from 0 to 600 amp. Fusetron's deliver 10 seconds (minimum) of time-delay at 500% of rated current (8 seconds for 1/10-30A sizes).
Bussmann Fusetron™ Time Delay Fuse, Current Limiting Renewable, Series: FRS-R, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 100 A, 600 VAC/300 VDC, 20/200 kA Interrupt, Class: RK5, 10 s at 500% Response, Blade Terminal, Holder Mount, Cartridge Body Type, Dual Element, Fiberglass, 1.11 in Dia x 7.88 in L Body Size
Body Size |
: |
1.11 in Dia x 7.88 in L |
Element |
: |
Dual |
Indicating/Non-Indicating |
: |
Non-Indicating |
Material |
: |
Fiberglass |
Mounting Type |
: |
Holder |
Rejection/Non-Rejection |
: |
Rejection |
Response Time |
: |
10 s at 500% |
Series |
: |
FRS-R |
Terminal Type |
: |
Blade |
Type |
: |
Current Limiting Renewable |
Amperage Rating |
: |
100 A |
Voltage Rating |
: |
600 VAC/300 VDC |
Interrupt Rating |
: |
20/200 kA |
Class |
: |
RK5 |
Body Type |
: |
Cartridge |
- Provides motor overload, ground fault and short circuit protection
- When used in circuits subject to surge currents such as those caused by motors, transformers and other inductive components, these fuses can be sized close to full-load amps to give maximum over current protection
- The time delay feature makes it possible to use fuse amperage ratings which are much smaller than those of non-time delay fuses
- Considerable cost savings occur by permitting the use of smaller size switches, panels and fuses themselves
- Provides a good deg of short circuit protection (greater current limitation) to help protect downstream components from high fault currents
- Gives motor running back-up protection to motors without extra cost
- Helps protect motors against burnout from overloads and single phasing when sized properly
- Simplifies and improves blackout prevention (selective co-ordination ratios)
- Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
-
Catalog
https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_c85790299cf54e7461bd1f247fc23e8817bf201e0cbc9266bf262bd79c0a3cd8.pdf
-
Line Drawing
https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_1423be417d2df19e2fe6f46a335f01eddc5cbbc202c4f2cbb79de8dce35fa8e7.pdf
-
Specification Sheet
https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_bff0c364c618e6b2b2cb3da4ac4263acf2b3d5ddeab4a0fead7612c33194ef38.pdf
-
Technical Bulletin
https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/Edison_REN_10_Technical_Bulletin.pdf
-
VIDEO LINK