Bussmann's UL Class RK5 Fusetron product offering provides energy efficient advanced protection with its dual-element, time-delay construction and is available with optional open fuse indication on select ratings. Available in both 250Vac and 600Vac, 200kA RMS Sym interrupting rating and sizes ranging from 0 to 600 amp. Fusetron's deliver 10 seconds (minimum) of time-delay at 500% of rated current (8 seconds for 1/10-30A sizes).
Bussmann Fusetron™ Renewable Fuse, Current Limiting Time Delay, Series: FRS-R, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 200 A, 600 VAC/300 VDC, 200/20 kAIC Interrupt, Class: RK5, 10 s at 500% Response, Blade End Terminal, Holder Mount, Cartridge Body Type, Dual Element, Fiberglass, 1.61 in Dia x 9.63 in L Body Size
Body Size |
: |
1.61 in Dia x 9.63 in L |
Element |
: |
Dual |
Indicating/Non-Indicating |
: |
Non-Indicating |
Material |
: |
Fiberglass |
Mounting Type |
: |
Holder |
Rejection/Non-Rejection |
: |
Rejection |
Response Time |
: |
10 s at 500% |
Series |
: |
FRS-R |
Terminal Type |
: |
Blade End |
Type |
: |
Current Limiting Time Delay |
Amperage Rating |
: |
200 A |
Voltage Rating |
: |
600 VAC/300 VDC |
Interrupt Rating |
: |
200/20 kAIC |
Class |
: |
RK5 |
Body Type |
: |
Cartridge |
- Provides motor overload, ground fault and short circuit protection
- When used in circuits subject to surge currents such as those caused by motors, transformers and other inductive components, these fuses can be sized close to full load amps to give maximum overcurrent protection
- The time delay feature makes it possible to use fuse amp ratings which are much smaller than those of non-time delay fuses
- Considerable cost savings occur by permitting the use of smaller size switches, panels and fuses themselves
- Provides a good degree of short circuit protection (greater current limitation) to help protect downstream components from high fault currents
- Gives motor running back-up protection to motors without extra costs
- Helps protect motors against burnout from overloads and 1 ph when sized properly
- Simplifies and improves blackout prevention (selective co-ordination ratios)
- Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
-
Catalog
https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_c85790299cf54e7461bd1f247fc23e8817bf201e0cbc9266bf262bd79c0a3cd8.pdf
-
Line Drawing
https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_1423be417d2df19e2fe6f46a335f01eddc5cbbc202c4f2cbb79de8dce35fa8e7.pdf
-
Specification Sheet
https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_571841d364c52afaa1e1ad09dc968c7802027c752d114a929b634478485a54d5.pdf
-
Technical Bulletin
https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/Edison_REN_10_Technical_Bulletin.pdf
-
VIDEO LINK
https://www.youtube.com/watch?v=YMvqUyoETXk