EATON MD93E92 MD93E92 EC | Fromm
Send Print
  1. pin-int

EATON MD93E92

EATON MD93E92 MD Series Type DT-3 Dry Ventilated Motor Drive Isolation Transformer, 460 Delta VAC Primary, 460Y/266 VAC Secondary, 93 kVA Power Rating, 60 Hz, 3 ph Phase

  • Manufacturer Name: Eaton
  • MPN: MD93E92
  • Brand Name: EATON
  • UPC: 786680331817
  • FEPN: MD93E92 EC
  • Min Order Qty: 1
  • Quantity Interval: 1
  • Inventory Availability loading

EATON motor drive isolation transformers are manufactured using high quality construction and are available in a wide range of ratings to meet specific voltage conversion requirements. They provide electrical isolation between the incoming line and drive circuitry, voltage conversion on input line to standard drive input voltages, minimize line disturbances caused by SCR firing and reduce short circuit currents and voltage line transients.

EATON Motor Drive Isolation Transformer, Type DT-3 Dry Ventilated, Series: MD Series, 460 Delta VAC Primary, 460Y/266 VAC Secondary, 93 kVA Power, 60 Hz Frequency, 3 ph, 2 Taps, Lug Connection, 916A Frame Circuit, Threaded Mounting, NEMA 2 Enclosure, 150 deg C, Steel Housing Material, 23.42 in L x 28.22 in W x 48.56 in H Dimensions

Circuit Type       :      916A Frame
Connection Type       :      Lug
Dimensions       :      23.42 in L x 28.22 in W x 48.56 in H
Enclosure Type       :      NEMA 2
Housing Material       :      Steel
Mounting Type       :      Threaded
Number of Taps       :      2
Series       :      MD Series
Temperature Rating       :      150 deg C
Type       :      Type DT-3 Dry Ventilated
Primary Voltage       :      460 Delta VAC
Secondary Voltage       :      460Y/266 VAC
Power Rating       :      93 kVA
Frequency Rating       :      60 Hz
Phase       :      3 ph
  • Thermal sensors embedded in coils can be wired to provide a signal to remote locations, indicating potential heating problems within the transformer coils
  • Get fast and easy connection with front accessible primary and secondary terminals
  • Easily identify terminals with clear labeling
  • Reduce installation time with slotted screw mounting holes in enclosure and cover
  • Reduce noise levels to meet NEMA ST-20 with sound dampening pads that isolate the core and coil from the case
  • Short term overload capability as required by ANSI
  • Core laminations of precision sheared silicon steel are hand stacked to ensure quiet operation
  • Terminations are clearly marked for easy identification
  • 3-phase transformers have one 5% full capacity tap above and below nominal voltage for incoming source adjustment
  • Full current neutral
  • Thermoguard protection embedded in coils of 3-phase models to indicate that high temperatures (approximately 190 deg C) are present
  • Three coil delta-wye configurations are used throughout the product line
  • Aluminum windings
  • 1 at +5% FCAN, 1 at -5% FCBN taps
  • pdfCatalog https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_44f85e021903699428c7decf474100a230319e0aa16f8792d2a2183ca227a751.pdf
  • pdfInstruction/Installation Manual https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/EATON_MD20E91_Manual.pdf
  • pdfSpecification Sheet https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_e5255a48642f521a932642f363f5dab2d9099f75d200dec2bfd6dbd3bb2fd7aa.pdf