Bussmann LPS-RK-50SP LPS-RK-50SP BU | Fromm
Send Print
  1. pin-int

Bussmann LPS-RK-50SP

Bussmann Low-Peak™ LPS-RK-50SP Current Limiting Time Delay Fuse, 50 A, 600 VAC/300 VDC, 300/100 kAIC Interrupt, RK1 Class, Cylindrical Body

  • Manufacturer Name: Eaton
  • MPN: LPS-RK-50SP
  • Brand Name: Bussmann
  • UPC: 051712548403
  • FEPN: LPS-RK-50SP BU
  • Min Order Qty: 1
  • Quantity Interval: 1
  • Inventory Availability loading

Ultimate protection Class RK1 dual element, current-limiting, time-delay fuses available with optional open fuse indication on select ratings. Time-delay 10 s (minimum) at 500% of rated current.

Bussmann Low-Peak™ Fuse, Current Limiting Time Delay, Series: LPS-RK, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 50 A, 600 VAC/300 VDC, 300/100 kAIC Interrupt, Class: RK1, 10 s at 500% Response, Ferrule End Terminal, Holder Mount, Cylindrical Body Type, Dual Element, Melamine, 1.06 in Dia x 5.5 in L Body Size

Body Size       :      1.06 in Dia x 5.5 in L
Element       :      Dual
Indicating/Non-Indicating       :      Non-Indicating
Material       :      Melamine
Mounting Type       :      Holder
Rejection/Non-Rejection       :      Rejection
Response Time       :      10 s at 500%
Series       :      LPS-RK
Terminal Type       :      Ferrule End
Type       :      Current Limiting Time Delay
Amperage Rating       :      50 A
Voltage Rating       :      600 VAC/300 VDC
Interrupt Rating       :      300/100 kAIC
Class       :      RK1
Body Type       :      Cylindrical
  • Fast short circuit protection and dual element, time delay performance provide ultimate protection
  • Reduces existing fuse inventory by up to 33% when upgrading to Low-Peak™ fuses
  • Consistent 2:1 ampacity ratios for all Low-Peak™ fuses make selective co-ordination easy
  • Time-delay permits sizing as close as 130% of motor full load amps (FLA) for back-up overload protection
  • Current limitation protects downstream components against damaging thermal and magnetic effects of short circuit currents
  • Protects against 1 ph motor damage
  • Proper sizing can provide "no damage" type 2 motor starter protection for NEMA and the international electrotechnical commission (IEC) motor controllers
  • Electrically isolated end caps for additional safety
  • pdfCatalog https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_732af43942f3b83bff965337812811f75f4fbe4cea1c1e2c389ad0fbbd748eec.pdf
  • pdfLine Drawing https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_f44d4d2e35a85073cbcbab97558df8546d8ab62b9337de79022438851efbbafb.pdf
  • pdfSpecification Sheet https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_6bcc075c7a3714550af22e508460330e9055103ecf55ae5b1a8f59fb1dc7d81e.pdf
  • videoVIDEO LINK https://www.youtube.com/watch?v=YMvqUyoETXk