Bussmann Low-Peak™ Time Delay Fuse, Current Limiting, Series: LPJ, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Non-Rejection, 40 A, 600 VAC/300 VDC, 300/100 kA Interrupt, Class: J, 10 s Response, Ferrule Terminal, Holder Mount, Cylindrical Body, Dual Element, Melamine, 1.06 in Dia x 2.38 in L Body Size
Body Size |
: |
1.06 in Dia x 2.38 in L |
Element |
: |
Dual |
Indicating/Non-Indicating |
: |
Non-Indicating |
Material |
: |
Melamine |
Mounting Type |
: |
Holder |
Rejection/Non-Rejection |
: |
Non-Rejection |
Response Time |
: |
10 s |
Series |
: |
LPJ |
Terminal Type |
: |
Ferrule |
Type |
: |
Current Limiting |
Amperage Rating |
: |
40 A |
Voltage Rating |
: |
600 VAC/300 VDC |
Interrupt Rating |
: |
300/100 kA |
Class |
: |
J |
Body Type |
: |
Cylindrical |
- Separate overload and short circuit elements provide time delay for sizing of high inrush loads linked with class J current limitation
- Selective coordination ratio of 2:1 (within Low-Peak® fuse family) prevents electrical shutdowns from extending beyond the failed circuit
- Series combination ratings with branch circuit breakers allows broad range of coverage, independent of breaker manufacturer
- Proper sizing can provide "No Damage" type 2 coordinated protection for NEMA® and IEC® motor controllers
- Space saving package for equipment down sizing
- Industry's only UL listed and CSA Certified fuse with a 300 kA interrupt rating that allows for simple, worry free installation in virtually any application
- Fast short circuit protection and dual element, time delay performance provide ultimate protection
- Reduces existing fuse inventory by up to 33% when upgrading to Low-Peak® fuses
- Consistent 2:1 ampacity ratios for all Low-Peak® fuses make selective coordination easy
- Long time delay minimizes needless fuse openings due to temporary overloads and transient surges
- Current limitation protects downstream components against damaging thermal and magnetic effects of short circuit currents
- Dual element fuses have lower resistance than ordinary fuses, hence they run cooler
- They can often be sized for back up protection against motor burnout from overload or single phasing if other overload protective devices fail
-