EATON MD075E96BCU

EATON MD075E96BCU Type DT-3 Dry Ventilated Drive Isolation Transformer, 575 Delta VAC Primary, 575Y/332 VAC Secondary, 7.5 kVA Power Rating, 60 Hz, 3 Phase

  • Manufacturer Name: Eaton
  • MPN: MD075E96BCU
  • Brand Name: EATON
  • UPC: 786685266855
  • FEPN: MD075E96BCU EC
  • Min Order Qty: 1
  • Quantity Interval: 1
  • Inventory Availability loading

EATON motor drive isolation transformers are available in a wide range of ratings to meet specific voltage conversion requirements. They provide electrical isolation between the incoming line and drive circuitry, voltage conversion on input line to standard drive input voltages, minimize line disturbances caused by SCR firing and reduce short-circuit currents and voltage line transients.

EATON Drive Isolation Transformer, Type DT-3 Dry Ventilated, Series: MD Series, 575 Delta VAC Primary, 575Y/332 VAC Secondary, 7.5 kVA, 60 Hz, 3 Phase, 2 Taps, Lug, Threaded Mount, Class R/220 deg C, NEMA 2, 80 deg C, Steel Housing, 16-1/2 in L x 23 in W x 30 in H

Connection Type       :      Lug
Dimensions       :      16-1/2 in L x 23 in W x 30 in H
Enclosure Type       :      NEMA 2
Housing Material       :      Steel
Insulation       :      Class R/220 deg C
Mounting Type       :      Threaded
Number of Taps       :      2
Series       :      MD Series
Temperature Rating       :      80 deg C
Type       :      Type DT-3 Dry Ventilated
Primary Voltage       :      575 Delta VAC
Secondary Voltage       :      575Y/332 VAC
Power Rating       :      7.5 kVA
Frequency Rating       :      60 Hz
Phase       :      3
  • Thermal sensors embedded in coils can be wired to provide a signal to remote locations, indicating potential heating problems within the transformer coils
  • Get fast and easy connection with front accessible primary and secondary terminals
  • Easily identify terminals with clear labeling
  • Reduce installation time with slotted screw mounting holes in enclosure and cover
  • Reduce noise levels to meet NEMA ST-20 with sound dampening pads that isolate the core and coil from the case
  • Short term overload capability as required by ANSI
  • Core laminations of precision sheared silicon steel are hand stacked to ensure quiet operation
  • 3 ph transformers have one 5% full capacity tap above and below nominal voltage for incoming source adjustment
  • Units are suitable for continuous operation in a 40 deg C ambient maximum
  • Full current neutral
  • Thermoguard protection embedded in coils of 3 ph models to indicate that high temperatures (approximately 190 deg C) are present, thermoguards consist of a set of NO dry contacts
  • 3 coil delta-wye configurations are used throughout the product line
  • Copper windings
  • 1 at +5% FCAN, 1 at -5% FCBN taps
  • pdfCatalog https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_44f85e021903699428c7decf474100a230319e0aa16f8792d2a2183ca227a751.pdf
  • pdfInstruction/Installation Manual https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/EATON_S10N04A05N_Manual.pdf
  • pdfSpecification Sheet https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_896613da587067cbf6eff4ce7378078c15b703827b10e51a4c0259ee4aa1716b.pdf