HPS Centurion® H1EM150KK30

HPS Centurion® H1EM150KK30 Energy Efficient Harmonic Mitigating Transformer, 480Y VAC Primary, 480Y/277 VAC Secondary, 150 kVA Power Rating, 60 Hz, 3 Phase

  • Manufacturer Name: Hammond Power Solutions
  • MPN: H1EM150KK30
  • Brand Name: HPS Centurion®
  • UPC: 803423047597
  • FEPN: H1EM150KK30 HP
  • Min Order Qty: 1
  • Quantity Interval: 1
  • Inventory Availability loading

HPS Centurion® energy efficient harmonic mitigating distribution transformers are rated for 600 VAC and below. Typical applications of severe non-linear loading conditions include data centers, internet service providers, telecom sites, call centers, broadcast centers, etc. Energy efficient harmonic mitigating transformers with zero sequence flux cancellation technology, is specifically designed to treat the harmonics generated by computer equipment and other non-linear, power electronic loads. Superior to K-rated and conventional transformers in reducing voltage distortion (flat topping) and power losses due to current harmonics created by 1-phase, non-linear loads such as computer equipment. Combining zero sequence flux cancellation with phase shifting treats 3rd, 5th, 7th, 9th, 15th, 17th and 19th, harmonics within its secondary windings.

HPS Centurion® Harmonic Mitigating Transformer, Energy Efficient, 480Y VAC Primary, 480Y/277 VAC Secondary, 150 kVA Power, 60 Hz Frequency, 3 ph, -30 deg Zigzag/Lug/Pad Connection, Floor Mounting, 220 deg C Insulation, NEMA 3R Enclosure, 30 to 40 deg C, 98.29 % Efficiency, 25-1/2 in L x 32 in W x 41 in H Dimensions

Connection Type       :      -30 deg Zigzag/Lug/Pad
Dimensions       :      25-1/2 in L x 32 in W x 41 in H
Efficiency       :      98.29 %
Enclosure Type       :      NEMA 3R
Insulation       :      220 deg C
Mounting Type       :      Floor
Temperature Rating       :      30 to 40 deg C
Type       :      Energy Efficient
Primary Voltage       :      480Y VAC
Secondary Voltage       :      480Y/277 VAC
Power Rating       :      150 kVA
Frequency Rating       :      60 Hz
Phase       :      3
  • Meets DOE 10 CFR Part 431 (TP1) and CSA C802.2 and Canadian energy efficiency regulations SOR/94-651 (and/or CSA C802.2) efficiencies at an operating range from 35% to 65% of rated load and under a non-linear load profile up to K20 in an operating range from 35% to 50%
  • Prevents voltage flat topping caused by non-linear loads
  • Reduces upstream harmonic currents
  • Eliminates transformer overheating and high operating temperatures
  • Eliminates primary winding circulating current
  • Saves energy by reducing harmonic losses
  • Maintains high energy efficiency even under non-linear loading conditions
  • Electrostatic shielding for high frequency noise attenuation
  • Lowers voltage distortion to prevent premature equipment failure
  • Restores ride through capability of computer equipment
  • Treats power quality harmonic issues which K-rated transformers do not address
  • Suitable for high K-factor loads
  • Reduces current distortion at UPS, generator or utility service
  • Improves upstream total power factor
  • Electrostatic shield and a 200% rated neutral in an indoor/outdoor rated enclosure
  • pdfCatalog https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_5a4424c2ffac7ac459ba110a582444dc8da2a820b93679aa940c1cbca1cfa9cc.pdf
  • pdfSDS https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_22e45150a9d90c4a88264a9f3827254a13a1d72df1f8d493eb38ac53c24249e7.pdf
  • pdfSpecification Sheet https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_7353f49b254d5aedf29711cd9d15345d4139d47c5f9590f5a5f13b7c012b0048.pdf
  • pdfWarranty Information https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_94a74aa0e49b4820adf62b27c533beb85c7e7a711101f7674fef1aa543215df1.pdf