EATON BRH230

EATON BRH230 Type BR High Magnetic Circuit Breaker, 120/240 VAC, 30 A, 22 kA Interrupt, 2 Poles, Common/Thermal Magnetic Trip

  • Manufacturer Name: Eaton
  • MPN: BRH230
  • Brand Name: EATON
  • UPC: 786676373609
  • FEPN: BRH230 EC
  • Min Order Qty: 1
  • Quantity Interval: 1
  • Inventory Availability loading

EATON type BR plug-in breakers in the standard 1 in per pole molded case and can be used as main and/or branch disconnect devices. All are CSA and UL listed. Typical ampacity range for BR breakers is 15 through 125 A.

EATON Circuit Breaker, Type BR High Magnetic, 120/240 VAC, 30 A, 60 Hz, 22 kA Interrupt, Common/Thermal Magnetic Trip, 2 Pole, 1 ph, Toggle Actuator, Box Lug/Clamp, 14 to 4 AWG Wire, Plug-On Mount, 40 deg C, 3 in L x 2 in W x 3 in H, Thermoset

Actuator Type       :      Toggle
Connection Type       :      Box Lug/Clamp
Dimensions       :      3 in L x 2 in W x 3 in H
Frequency Rating       :      60 Hz
Material       :      Thermoset
Mounting Type       :      Plug-On
Phase       :      1 ph
Temperature Rating       :      40 deg C
Type       :      Type BR High Magnetic
Wire Size       :      14 to 4 AWG
Voltage Rating       :      120/240 VAC
Amperage Rating       :      30 A
Interrupt Rating       :      22 kA
Number of Poles       :      2
Trip Type       :      Common/Thermal Magnetic
  • All are type IC (interchangeable) devices, several ratings are SWD and HARC approved
  • Each pole of the circuit breaker will provide inverse time delay overload and instantaneous short circuit protection by means of both thermal and magnetic sensors
  • The circuit breaker calibration shall not be affected by environmental changes in relative humidity
  • All circuit breakers shall be operated by a toggle type handle and multipole circuit breakers shall have an internal common trip mechanism
  • Contacts shall be of non-welding silver alloy
  • All circuit breakers shall have the trip rating inscribed on the handle on each circuit breaker pole
  • Circuit breakers shall be completely enclosed in a molded case of thermoset material
  • All terminals shall be listed for use with copper/aluminum conductors
  • Terminals shall be of the box lug or clamp type design
  • The terminals shall meet UL 486B requirements and shall be suitable for use with either 60 or 75 deg C wire