EATON CH24L3225D CH24L3225D EC | Fromm
Send Print
  1. pin-int

EATON CH24L3225D

EATON CH24L3225D 3-Phase Standard Main Lug Loadcenter, 208Y/120 VAC, 225 A, 24 Poles, 35 kA Interrupt

  • Manufacturer Name: Eaton
  • MPN: CH24L3225D
  • Brand Name: EATON
  • UPC: 782113097671
  • FEPN: CH24L3225D EC
  • Min Order Qty: 1
  • Quantity Interval: 1
  • Inventory Availability loading

EATON CH 3/4 in loadcenters enclose CH breakers for power distribution and circuit protection in residential and light commercial applications. Also called a breaker box, electrical box or even a fuse box, the main function is to take electricity supplied by the utility and distribute it throughout the home to feed lights and receptacles. They are used on services providing no more than 240 VAC and are available with bus rated 40 to 600 A. Covers are available as surface, flush or combination.

EATON Main Lug Loadcenter, 3-Phase Standard, 208Y/120 VAC, 225 A, 24 Pole, 35 kA Interrupt, 24 Circuits, CH Breaker, 4-Wire Wiring Configuration, 24 Spaces, 4 AWG to 300 kcmil Wire, NEMA 1, NEMA D Enclosure Box, Metal Housing, 29.13 in L x 14.31 in W x 3.88 in H

Breaker Type       :      CH
Dimensions       :      29.13 in L x 14.31 in W x 3.88 in H
Enclosure Box Size       :      NEMA D
Enclosure Type       :      NEMA 1
Housing Material       :      Metal
Number of Circuits       :      24
Number of Spaces       :      24
Type       :      3-Phase Standard
Wire Size       :      4 AWG to 300 kcmil
Wiring Configuration       :      4-Wire
Voltage Rating       :      208Y/120 VAC
Amperage Rating       :      225 A
Number of Poles       :      24
Interrupt Rating       :      35 kA
  • One-piece silver flash plated copper bus provides superior conductivity throughout the entire product line
  • Steel backpan provides positive, reliable mounting
  • Unique sandalwood finish provides an esthetically appealing, scratch resistant powder coating
  • Type CH breakers include an industry exclusive "trip to Off" feature that allows a homeowner to easily identify a tripped circuit breaker
  • It accommodates copper/aluminum wire at 60 to 75 deg C
  • Copper bus
  • Overhead/underground feed applications
  • pdfCatalog https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_4699c4093f200f15c8feec0c1d17577c692ad449e7fa8bead4e77755afaf41b2.pdf
  • pdfInstruction/Installation Manual https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_ca16bd8f5db476d34fa75b41ece3caa72dc141327f68d7a38a79a60d860a17b7.pdf
  • pdfSpecification Sheet https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_9f5eef63a4ef3bde66a52b91109369d5468b73686dbd782da5334aa232777443.pdf